The Soltree ST2-VA2-2 combines overvoltage, undervoltage and overcurrent protection with an LED display and adjustable settings. The pictured white-housing version has a black display panel with rectangular control buttons and a red on/off button. It mounts on a DIN rail in an electrical distribution enclosure.

Protection, display and controls

  • Overvoltage, undervoltage and overcurrent protection
  • LED voltage and current display in the catalogue AC configuration
  • Adjustable protection thresholds, recovery settings and delays
  • SET, up, down and on/off controls on the front panel
  • Automatic voltage recovery reconnection when enabled, subject to the selected recovery settings and delay
  • DIN-rail mounting and logo customization on request

Catalogue AC configuration references

The following values come from the ST2-VA2-2 catalogue entry. They describe the documented AC configuration and its settings. Confirm the supply voltage, current rating and required settings for the version you intend to order. The current list describes catalogue configurations and does not confirm stock availability.

ST2-VA2-2: catalogue technical and setting references
Item Catalogue reference
Catalogue AC rated supply 220 V AC
Catalogue maximum operating current 40 / 63 / 80 / 100 A
Overvoltage setting range 130–300 V AC
Undervoltage setting range 80–210 V AC
Overvoltage recovery setting 125–295 V
Undervoltage recovery setting 85–215 V
Voltage hysteresis 5 V
Power-on delay setting 1–999 s
Recovery delay setting 1–999 s
Voltage trip-delay setting 0.1–10 s
Overcurrent trip-delay setting 0.1–10 s
Overvoltage trip delay: technical-table reference 0.5 s
Voltage accuracy: catalogue reference <1%
Maximum operating phase voltage: catalogue label 350 V
Altitude ≤2,000 m
Permissible relative humidity <50% at 40°C, without condensation
Ambient temperature −25°C to +55°C

The overvoltage and undervoltage ranges above are protection-setting ranges, not the operating supply-voltage range. The 0.5 s technical-table entry is an overvoltage reference alongside the adjustable trip-delay menus; it is not a fixed response-time guarantee for every fault or supplied version. The voltage-accuracy reference has no stated test conditions and does not specify current accuracy. The catalogue label “maximum operating phase voltage” does not establish a continuous supply range, insulation withstand or surge rating.

Displayed values in product images do not define the rated supply voltage or current.

Customization and ordering

Logo customization is available on request. A 110 V version can also be customized. Its electrical ratings, protection thresholds, recovery settings and load suitability must be confirmed separately; the catalogue AC values above do not specify a 110 V version.

For a quotation, send the model ST2-VA2-2, required supply voltage and current rating, intended load, quantity, destination and logo requirements. We can then check the product configuration and supply details for your order.

Contact Soltree to confirm the version for your order, or browse the product range.

Soltree logo round

Soltree supplies low-voltage electrical products for business and project needs. Contact our team for product specifications, model information and quotations.

soltree electrical blog

Product & Supply Enquiries

Tell us the required model, electrical ratings, quantity and destination. We can check available product options and supply details for your enquiry.

Quote Now

Get Free Sample,Get Competitive Prices